12

Basic drive functions

12.12

Brake control

554

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.12.2

Parameter setting

• Parameterisation dialog in »Engineer«: Tab Application parameters  Dialog level Overview

All basic functions Brake control

• Short overview of parameters for brake control:

Danger!

A faultless brake control function requires a correct setting of the different deceleration

times in the following parameters!
If the delay times are set incorrectly, a faulty control of the motor holding brake may be

caused!
In the case of the basic functions

Manual job, encoderless

( 446)

and

Pole position

identification

( 602)

, the number of available operating modes of the holding brake is

limited. Please refer to the danger notes in the chapters indicated.

Parameter

Info

C02580

Operating mode brake

C02581

Threshold - brake activation

C02582

Brake resp. to pulse inhibit

C02583

Status input monitoring

C02585

Brake control polarity

C02586

Starting torque 1

C02587

Starting torque 2

C02588

Source of starting torque

C02589

Brake closing time

C02590

Brake opening time

C02591

Waiting time - status monitoring

C02593

Waiting time - brake activation

C02594

Test torque

C02595

Permissible angle of rotation

C02596

Grinding speed

C02597

Accel./decel. time - grinding

C02598

Grinding ON time

C02599

Grinding OFF time

C02600

Acceleration time feedf. control

C02601

Reference for acceleration time of brake

C02602

Source for feedf. control brake

C02603

Threshold 1 for opening brake

C02604

Threshold 2 for opening brake