7encoder evaluation – Lenze E94AxPExxxx User Manual

Page 302

Advertising
background image

7

Encoder evaluation

7.3

Parameter setting

302

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of the parameters:

Parameter

Info

Lenze setting

Value Unit

C00422

Encoder type

SSI encoder

C00423

SSI encoder: Bit rate

400 kbps

C00424

SSI encoder: Data word length

24 Bit

C00435/1

SSI enc.: Partword 1 start

0

C00436/1

SSI enc.: Partword 1 length

24

C00437/1

SSI enc.: Partword 1 coding

gray coded

C00490

Position encoder selection

Encoder on X8

C00495

Motor encoder selection

Resolver on X7

C02522

Gearbox factor numerator: position encoder

1200

C02523

Gearbox factor denominator: position encoder

400

C02524

Feed constant

1200 mm

C02570

Position control structure

Position controller is active

C05271

Encoder evaluation

32-bit encoder signal

C05272

Encoder mounting position

Left

C05273

Single turn resolution

4096 Steps/rev

C05274

Resolution Multiturn

4096 Rev

Advertising