12 basic drive functions – Lenze E94AxPExxxx User Manual
Page 433
![background image](/manuals/566084/433/background.png)
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
433
12
Basic drive functions
12.3
Quick stop
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
A. Initial situation: basic function "Speed follower" is enabled and active.
B. QSP_bActivateDCBrake control input is set to TRUE through the application to activate DC-
injection braking.
C. DC-injection braking is executed with the braking current set in
D. QSP_bActivateDCBrake control input is reset to FALSE through the application to deactivate DC-
injection braking.
E. The flying restart process starts, i.e. the controller calculates the output frequency required for
the momentary motor speed, then connects to the system, and accelerates the motor to the
defined setpoint again.