14.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Cam data: invalid product number [0x00b80035]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

53

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

A product number has been created in the system block

LS_CamInterface

which is not in the range of product

number of the downloaded cam data.

Check number of products.

• The product number must be higher than 0 and lower

than the value displayed in

C02908

.

C02908

displays the highest product number +1 of

the cam data currently being processed.