Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Cam data: invalid product number [0x00b80035]
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
53
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
A product number has been created in the system block
which is not in the range of product
number of the downloaded cam data.
Check number of products.
• The product number must be higher than 0 and lower
than the value displayed in
.
•
displays the highest product number +1 of
the cam data currently being processed.