10

"CAN on board" system bus

10.10

Implemented CANopen objects | I-1401

396

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1401

Communication parameter for receiving process data via RPDO2

• For assignment of the data telegram see object

I-1400

.

I-1402

Communication parameter for receiving process data via RPDO3

• For assignment of the data telegram see object

I-1400

.

Index:

I-1401

Name:

RPDO2 communication parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

5

- (read access only)

ro

U8

1: COB-ID used by RPDO

0x300 + node ID

0

4294967295 rw

U32

2: Transmission type

254

0

255 rw

U8

3: Inhibit time

-

- (not used for RPDOs)

rw

U16

4: Compatibility entry

-

- (reserved, read or write access leads to error message

0x06090011)

rw

U8

5: Event timer

-

- (not used for RPDOs)

rw

U16

Subindex

Meaning

Lenze code

1

RPDO2 identifier

• The basic setting is according to the "Predefined

Connection Set": Identifier = 0x300 + node ID

C00321/2

2

RPDO Transmission type according to DS301 V4.02

Transmission type ( 348)

C00323/2

Index:

I-1402

Name:

RPDO3 communication parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

5

- (read access only)

ro

U8

1: COB-ID used by RPDO

0x400 + node ID

0

4294967295 rw

U32

2: Transmission type

254

0

255 rw

U8

3: Inhibit time

-

- (not used for RPDOs)

rw

U16

4: Compatibility entry

-

- (reserved, read or write access leads to error message

0x06090011)

rw

U8

5: Event timer

-

- (not used for RPDOs)

rw

U16

Subindex

Meaning

Lenze code

1

RPDO3 identifier

• The basic setting is according to the "Predefined

Connection Set": Identifier = 0x400 + node ID

C00321/3

2

RPDO Transmission type according to DS301 V4.02

Transmission type ( 348)

C00323/3