Basic drive functions

12.13

Cam data management

598

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

How to change a cam:

1. Go to

C02911

and set the product number of the product to be edited.

2. Go to

C02940

and set the track number of the cam track to be edited.

Tip!
The cam type is displayed in

C02941

and the number of cams of the selected cam data is

displayed in

C02942

.

3. Go to

C02943

and set the cam to be edited.

4. Change the desired parameters of the selected cam:

C02944

: Cam position X0

C02945

: Cam position X1

C02946

: Cont Time (for position/time cams)

How to change a position mark:

1. Go to

C02911

and set the product number of the product to be edited.

2. Go to

C02960

and set the track number of the position track to be edited.

Tip!
In

C02962

the number of the position marks of the position data selected is shown.

3. Set the position mark to be edited in

C02963

.

4. Change the desired parameters of the selected position mark:

C02964

: x position

C02965

: y position

Advertising