C02104

C02105

C02108

C02109

C02110

Parameter | Name:

C02104 | Program auto-start

Data type: UNSIGNED_32

Index: 22471

d

= 57C7

h

Danger!

The controller enable generated by the application via a connection of the terminal 28 (RFR) with one of the digital

outputs DIGOUT_bOut(x) is not permissible if the following functions are active: "Auto-start after mains ON"

(

C00142

= "1") and "Program auto-start after mains switching" (

C02104

= "1")

If this is not observed, the controller can start automatically after mains connection!

Automatic restart after mains connection

Activate application

Selection list

(Lenze setting printed in bold)

0 Off
1 Autom. after mains connection

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02105 | Service code

Data type: BITFIELD_8

Index: 22470

d

= 57C6

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C02108 | Program status

Data type: UNSIGNED_8

Index: 22467

d

= 57C3

h

Selection list

(read only)

1 Program stopped
0 Program is running
2 Program stopped at breakpoint

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02109 | Program runtime

Data type: UNSIGNED_16

Index: 22466

d

= 57C2

h

Display range

(min. value | unit | max. value)

0

μs

65535

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02110 | User code memory load

Data type: UNSIGNED_32

Index: 22465

d

= 57C1

h

Display range

(min. value | unit | max. value)

0

%

100

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1