C00072 | speed contr.d component, C00074 | feedfwd. ctrl. - current contr, C00075 | current controller gain – Lenze E94AxPExxxx User Manual

Page 764: C00076 | current contr. reset time, C00077 | field controller gain, C00078 | field contr. reset time, C00075, C00076, Are not alte, C00072

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00072

764

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00072

C00074

C00075

C00076

C00077

C00078

Parameter | Name:

C00072 | Speed contr.D component

Data type: UNSIGNED_32

Index: 24503

d

= 5FB7

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

ms

3.00 0.00 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00074 | Feedfwd. ctrl. - current contr.

Data type: UNSIGNED_8

Index: 24501

d

= 5FB5

h

Selection list

(Lenze setting printed in bold)

0 Deactivate feedfwd. ctrl
1 Activate feedfwd. ctrl

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00075 | Current controller gain

Data type: UNSIGNED_32

Index: 24500

d

= 5FB4

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

V/A

750.00 105.00 V/A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00076 | Current contr. reset time

Data type: UNSIGNED_32

Index: 24499

d

= 5FB3

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

ms

2000.00 2.00 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00077 | Field controller gain

Data type: UNSIGNED_32

Index: 24498

d

= 5FB2

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A/Vs

50000.00 165.84 A/Vs

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00078 | Field contr. reset time

Data type: UNSIGNED_32

Index: 24497

d

= 5FB1

h

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

6000.0 15.1 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Advertising