Priorisation of the limited speeds
• If several limited speeds are requested at the same time, the lowest speed with the greatest
deceleration and the lowest S-ramp time is approached from the parameters of the requested
limited speeds.
12.11.2.7 Limited increment for manual jog
Via
the maximum permissible distance (limited increment) for the basic function "
" can be set.
• The request "Limited increment" is effected via the input LIM_dwControl, generally by the
control word of the safety module. If no safety module is available, the control word for the
input LIM_dwControl can also be generated by means of an inverter.
• In
the maximum permissible distance in [increments] is displayed.