14 diagnostics & fault analysis, 7 error messages of the operating system 652 – Lenze E94AxPExxxx User Manual

Page 652

Advertising
background image

14

Diagnostics & fault analysis

14.7

Error messages of the operating system

652

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x00780003

7864323

Motor load I²xt > C00120

Fault

-

0x00780002

7864322

Motor load I²xt > C00127

Warning

C00606

0x007b0038

8060984

Motor parameter identification cancelled

Fault

-

0x007b0025

8060965

Motor temperature: Module selected in C01193 is not available

Fault

-

0x007b001e

8060958

Motor: actual current > C00620

Fault

C00619

0x007b0020

8060960

Motor: actual speed > C00596

Fault

C00607

0x007b000b

8060939

Motor: Calculated e.m.f. factor unrealistic

Information

-

0x007b000d

8060941

Motor: Calculated flux factor unrealistic

Information

-

0x007b0019

8060953

Motor: Calculated leakage inductance unrealistic

Information

-

0x007b0001

8060929

Motor: Calculated motor impedance unrealistic

Information

-

0x007b0002

8060930

Motor: Calculated mutual inductance unrealistic

Information

-

0x007b000a

8060938

Motor: Calculated mutual inductance unrealistic

Information

-

0x007b0009

8060937

Motor: Calculated rotor resistance unrealistic

Information

-

0x007b000c

8060940

Motor: Calculated rotor time constant unrealistic

Information

-

0x007b0006

8060934

Motor: Device current too low for rated magnetisation

Information

-

0x00770003

7798787

Motor: Overtemperature

Fault

C00583

0x007b0004

8060932

Motor: Phase resistance too high

Information

-

0x0077000f

7798799

Motor: PTC has triggered

No response

C00585

0x007b0007

8060935

Motor: rated current < rated magnetisation current

Information

-

0x00770002

7798786

Motor: temperature > C00121

Warning

C00584

0x0077000c

7798796

Motor: thermal detector is defective

Fault

C00594

0x008c0017

9175063

MXI1: CAN module is missing or incompatible

Fault

C00615/2

0x008c0013

9175059

MXI1: Digital frequency module is missing or incompatible

Fault

C00615/2

0x008c0011

9175057

MXI1: Ethernet module is missing or incompatible

Fault

C00615/2

0x008c0015

9175061

MXI1: ICM module is missing or incompatible

Fault

C00615/2

0x00680004

6815748

MXI1: Module changed during operation

Warning locked

-

0x00680015

6815765

MXI1: Module has been changed

Information or warning locked if

the hardware type has also

changed.

-

0x0068000a

6815754

MXI1: Module is defective or missing

Fault

-

0x008c000d

9175053

MXI1: Module is missing or incompatible

Fault

-

0x008c000f

9175055

MXI1: PROFIBUS module is missing or incompatible

Fault

C00615/2

0x00680010

6815760

MXI1: Wrong module

System fault

-

0x008c0018

9175064

MXI2: CAN module is missing or incompatible

Fault

C00615/3

0x008c0014

9175060

MXI2: Digital frequency module is missing or incompatible

Fault

C00615/3

0x008c0012

9175058

MXI2: Ethernet module is missing or incompatible

Fault

C00615/3

0x008c0016

9175062

MXI2: ICM module is missing or incompatible

Fault

C00615/3

0x00680005

6815749

MXI2: Module changed during operation

Warning locked

-

0x00680016

6815766

MXI2: Module has been changed

Information or warning locked if

the hardware type has also

changed.

-

0x0068000b

6815755

MXI2: Module is defective or missing

System fault

-

0x008c000e

9175054

MXI2: Module is missing or incompatible

Fault

-

0x008c0010

9175056

MXI2: PROFIBUS module is missing or incompatible

Fault

C00615/3

0x00680011

6815761

MXI2: Wrong module

System fault

-

0x00b8000a

12058634

Negative direction of rotation limited

Information

C02716/1

0x00b80002

12058626

Negative limit switch has triggered

Quick stop by trouble

-

0x00b80008

12058632

Negative software limit switch overtravelled

Quick stop by trouble

C02716/2

0x006a0003

6946819

New applications loaded

Information

-

0x00910002

9502722

No heartbeat signal detected

System fault

-

0x0090000a

9437194

No parameters for module in MXI1

Fault

C00615/2

0x0090000b

9437195

No parameters for module in MXI2

Fault

C00615/3

0x007b0010

8060944

Overcurrent detected

Fault

-

hex

dec

Error message

Response (Lenze setting)

can be set in