Parameter list | C00781

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00781

C00782

C00783

C00784

C00786

Parameter | Name:

C00781 | MCTRL_dwMaxMotorSpeed

Data type: UNSIGNED_32

Index: 23794

d

= 5CF2

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0

rpm

480000

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00782 | MCTRL_dwMaxMotorTorque

Data type: UNSIGNED_32

Index: 23793

d

= 5CF1

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0.000

Nm

2147483.647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C00783 | MCTRL_dwMotorVoltageAct

Data type: UNSIGNED_32

Index: 23792

d

= 5CF0

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0

V

2000

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00784 | MCTRL_dnMotorFreqAct

Data type: INTEGER_32

Index: 23791

d

= 5CEF

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-800.0

Hz

800.0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00786 | MCTRL_dnIxtLoad

Data type: INTEGER_32

Index: 23789

d

= 5CED

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-200.00

%

200.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100