Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

911

15

Parameter reference

15.2

Parameter list | C02718

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02718

C02719

C02720

C02730

Parameter | Name:

C02718 | LIM_dnState

Data type: INTEGER_32

Index: 21857

d

= 5561

h

Status of the basic function "

Limiter

".

Display range

(min. value | unit | max. value)

0

1

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02719 | Limiter: Dig. signals

Data type: UNSIGNED_32

Index: 21856

d

= 5560

h

Display of the digital input signals of the basic function "

Limiter

".

Selection list

(read only)

0 FALSE
1 TRUE

Subcodes

Info

C02719/1

LIM_bLimitSwitchPositive

C02719/2

LIM_bLimitSwitchNegative

C02719/3

LIM_bActivateLimitedSpeed1

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02720 | observation software limit positions

Data type: UNSIGNED_32

Index: 21855

d

= 555F

h

Basic function "

Limiter

"

Selection list

(Lenze setting printed in bold)

0 Based on set value
1 Based on set and actual value

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02730 | Analog inputs: Gain

Data type: INTEGER_32

Index: 21845

d

= 5555

h

Setting range

(min. value | unit | max. value)

-200.00

%

200.00

Subcodes

Lenze setting

Info

C02730/1

100.00 %

Gain - analog input 1

C02730/2

100.00 %

Analog input 2: Gain

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100