36 activate parameter set 1, 5drive interface – Lenze E94AxPExxxx User Manual

Page 132

Advertising
background image

5

Drive interface

5.2

Device commands

132

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.36

Activate parameter set 1 ... 4

In addition to the start parameters, up to four further parameter sets can be stored in the memory

module for each application. Like this you can for instance define different controller settings for an

application, which are then simply activated via device command, if required.
The following device commands can be used to activate the parameter set 1 ... 4 for the active

application (if available on the memory module):

C00002

= "201: Activate parameter set 1"

C00002

= "202: Activate parameter set 2"

C00002

= "203: Activate parameter set 3"

C00002

= "204: Activate parameter set 4"

[5-20] Example: "Activate parameter set 1" function

• Only possible when the application has stopped and the controller is inhibited.
• All parameter changes of the previously active parameter set carried out since the last saving

will get lost!

• These device commands only affect the settings of the operating system, application and

module parameters, the active application remains unchanged.

* In this example, application 1 is the active application

PS 4

PS 3

PS 2

Application 2

PS 1

PS

PS 4

PS 3

PS 2

Memory module MM

PS

9400

PS

RAM

Firmware

Application 1*

Application 1*

PS

PS 1

Advertising