background image

13

Oscilloscope

13.4

Operation

618

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.4.4

Starting recording

Click Start to start recording.

To obtain a maximum sampling rate when recording the variable values, the data are first stored in

the measured data memory of the controller and then transferred as a data record to the PC. The

current recording status is shown in the status bar.

Edge

If the trigger source is a channel or a variable, you can choose between the following trigger

modes:

Positive edge For triggering on a BOOL variable:

• Trigger activation requires a FALSE-TRUE transition.

For triggering on a different variable:

• For trigger activation, the selected trigger value must be exceeded.

Negative edge For triggering on a BOOL variable:

• Trigger activation requires a TRUE-FALSE transition.

For triggering on a different variable:

• For trigger activation, the selected trigger value must be fallen below.

Change For triggering on a BOOL variable:

• Trigger activation requires a state change.

For triggering on a different variable:

• For trigger activation, the current value must be different than the last value.

Setting

Function

Note!

Starting the recording mode is only possible when an online connection has been

established to the controller.