15.2

Parameter list | C00055

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00055

C00056

C00057

C00058

Parameter | Name:

C00055 | Phase currents

Data type: INTEGER_32

Index: 24520

d

= 5FC8

h

Display range

(min. value | unit | max. value)

-500.00

A

500.00

Subcodes

Info

C00055/1

Phase zero system

C00055/2

Phase U

C00055/3

Phase V

C00055/4

Phase W

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00056 | Torque setpoint

Data type: INTEGER_32

Index: 24519

d

= 5FC7

h

Display range

(min. value | unit | max. value)

-21474836.47

Nm

21474836.47

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00057 | Torque

Data type: UNSIGNED_32

Index: 24518

d

= 5FC6

h

Display range

(min. value | unit | max. value)

0.000

Nm

2147483.647

Subcodes

Info

C00057/1

Maximum torque

• With regard to the selected motor and the max. short-

time output current of the device.

C00057/2

Motor reference torque

• Torque at maximum current (

C00022

).

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C00058 | Pole position

Data type: INTEGER_32

Index: 24517

d

= 5FC5

h

Setting range

(min. value | unit | max. value)

-179.9

°

179.9

Subcodes

Lenze setting

Info

C00058/1

-90.0 °

Resolver pole position

C00058/2

0.0 °

Encoder pole position

C00058/3

0.0 °

Module pole position

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10