15.2

Parameter list | C02577

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02577

C02578

C02579

C02580

Parameter | Name:

C02577 | External actual position

Data type: INTEGER_32

Index: 21998

d

= 55EE

h

Encoder evaluation

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02578 | Offset actual pos. value/setp.

Data type: INTEGER_32

Index: 21997

d

= 55ED

h

Encoder evaluation

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02579 | Encoder eval.: Dig. signals

Data type: UNSIGNED_32

Index: 21996

d

= 55EC

h

Display of the digital signals of the

encoder evaluation

.

Selection list

(read only)

0 FALSE
1 TRUE

Subcodes

Info

C02579/1

FDB_bResolverError

C02579/2

FDB_bSinCosSignalError

C02579/3

FDB_bEncoderComError

C02579/4

FDB_bResetPosFollowingError

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02580 | Operating mode brake

Data type: UNSIGNED_32

Index: 21995

d

= 55EB

h

Basic function "

Brake control

"

Selection list

(Lenze setting printed in bold)

0 Brake control off
1 Directly with brake module
2 Autom. with brake module

11 Directly - external switching
12 Autom. - external switching
22 Autom. - DC brake

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1