Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

179

6

Motor interface

6.3

Adjusting motor and controller to each other

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

After successful completion...
...the controller is inhibited automatically and the pole position determined for the activated

feedback system is set in the corresponding subcode of

C00058

.

• For a permanent acceptance of the identified pole position, the parameter set must be saved

(

C00002

= "11: Save start parameters").

• The next controller inhibit and subsequent controller enable serve to cancel the controller

inhibit automatically set by the procedure (e.g. by first executing the device command

C00002

= "41: Inhibit controller" and then executing the device command

C00002

= "42: Enable

controller").

In the event of an error
If an error occurs during the procedure or the pulse inhibit gets active (e.g. due to short-time

undervoltage), the procedure is terminated with controller inhibit without making a change in

C00058

.

If the machine was braked or blocked during the procedure, this will be recognised at the end of the

measurement and no change is made in

C00058

.

If the pole position identification is aborted, the response parameterised in

C00640

(Lenze setting:

"Fault"") is triggered and "Pole position identification cancelled" is entered in the logbook of the

controller.

Tip!
The identification of pole position is additionally available as a basic function in the form

of the

LS_PolePositionIdentification

system block.

Basic drive functions:

Pole position identification

( 602)