1 general information, 1 reading out motor data from the controller, General information – Lenze E94AxPExxxx User Manual

Page 165: Reading out motor data from the controller, 6motor interface

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

165

6

Motor interface

6.1

General information

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.1

General information

6.1.1

Reading out motor data from the controller

If the Lenze motor connected to the controller has an electronic nameplate (ENP), the motor does

not need to be selected in the »Engineer« motor catalogue.

• With the first switch-on of the controller all motor data are automatically read out from the

electronic nameplate of the motor and at first are saved temporarily within the controller.

• For a permanent acceptance of the motor data, the parameter set must be saved (

C00002

= "11:

Save start parameters").

• If there is an online connection between »Engineer« and the controller, the motor data can be

accepted from the controller to the »Engineer« project.

How to read out the motor data from the controller:

1. Establish an online connection between »Engineer« and controller.
2. Select the Application parameters tab and change to the Overview Motor Motor dialog

level.

3. Click on the From Drive button.

• Then the motor data are read out of the controller and directly written into the

corresponding codes of the »Engineer« project.

Display parameters for electronic nameplate (ENP)

Parameter

Info

Lenze setting

Value Unit

C00186

ENP: Identified motor type

-

C00187

ENP: Identified serial number

-

C00188

ENP: Status

-

Advertising