C02544 | reference speed, C02545 | reference s-ramp time, C02547 | di_dnstate – Lenze E94AxPExxxx User Manual

Page 878: C02548 | di_berrors, C02548/1, C02548/2, C02548/3, C02548/4, C02547, C02545

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02544

878

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02544

C02545

C02547

C02548

Parameter | Name:

C02544 | Reference speed

Data type: INTEGER_32

Index: 22031

d

= 560F

h

Drive interface

Display range

(min. value | unit | max. value)

-214748.3647

Unit/s

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02545 | Reference S-ramp time

Data type: UNSIGNED_32

Index: 22030

d

= 560E

h

From software version V2.0

Drive interface

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

2147483.647 0.001 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02547 | DI_dnState

Data type: INTEGER_32

Index: 22028

d

= 560C

h

Bit coded status of the

drive interface

.

Display range

(min. value | unit | max. value)

-2147483648

2147483647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02548 | DI_bErrors

Data type: UNSIGNED_32

Index: 22027

d

= 560B

h

Display of the digital error signals of the

drive interface

.

Selection list

(read only)

0 FALSE
1 TRUE

Subcodes

Info

C02548/1

DI_bResetError1

C02548/2

DI_bResetError2

C02548/3

DI_bResetError3

C02548/4

DI_bSetExternError

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising