C00003 | device command status, C00003, Us in – Lenze E94AxPExxxx User Manual

Page 749: C00002, Is in, 15 parameter reference

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

749

15

Parameter reference

15.2

Parameter list | C00003

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00003

Parameter | Name:

C00003 | Device command status

Data type: UNSIGNED_32

Index: 24572

d

= 5FFC

h

Display of the number/status of the device command last executed (

C00002

).

• The number of the command is situated in the upper 16 bits (for the meaning of the number see code

C00002

).

• The result of the command stands in the lower 16 bits.

Note:

Before switching off the supply voltage after a device command has been executed, check the successful execution

of the device command via the status display in

C00003

!

The meaning of the status display in

C00003

can be obtained from the subchapter for the corresponding device

command in chapter "

Device commands

".

Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Status

Meaning

Device command

0 Device command executed successfully

0:

Load Lenze setting

1 General error

34050 Device command in process
39424 CAN fault

... ...

39679 CAN fault
65536 Device command executed successfully

1:

Load start parameters

65537 General error
99371 Fault while reading the parameter set partition
99374 No memory module available
99586 Device command in process

104960 CAN fault

... ...

105215 CAN fault
131072 Device command executed successfully

2:

ETS: Load plant data

131073 General error
165122 Device command in process
327680 Device command executed successfully

5:

Activate application

327681 General error
361730 Device command in process
458752 Device command executed successfully

7:

Save selected application

458753 General error
492802 Device command in process

Advertising