Parameter reference

15.2

Parameter list | C02962

934

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02962

C02963

C02964

C02965

C02996

C02997

Parameter | Name:

C02962 | Number of Pos Data Points

Data type: UNSIGNED_32

Index: 21613

d

= 546D

h

Changing cam data via parameterisation

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02963 | Pos Data Point Choice

Data type: UNSIGNED_32

Index: 21612

d

= 546C

h

Changing cam data via parameterisation

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02964 | Change Pos Data Point X

Data type: INTEGER_32

Index: 21611

d

= 546B

h

Changing cam data via parameterisation

Setting range

(min. value | unit | max. value)

Lenze setting

-214748.3647

Unit

214748.3647 0.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02965 | Change Pos Data Point Y

Data type: INTEGER_32

Index: 21610

d

= 546A

h

Changing cam data via parameterisation

Setting range

(min. value | unit | max. value)

Lenze setting

-214748.3647

Unit

214748.3647 0.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02996 | Service code

Data type: UNSIGNED_32

Index: 21579

d

= 544B

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C02997 | Service code

Data type: UNSIGNED_32

Index: 21578

d

= 544A

h

This code is for device-internal use only and must not be written to by the user!