C02558

C02559

C02560

C02561

C02562

Parameter | Name:

C02558 | Pos. contr. output

Data type: INTEGER_32

Index: 22017

d

= 5601

h

Motor interface

Display range

(min. value | unit | max. value)

-214748.3647

Unit/s

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02559 | Internal torque limits

Data type: INTEGER_32

Index: 22016

d

= 5600

h

Motor interface

Display range

(min. value | unit | max. value)

-200.00

%

200.00

Subcodes

Info

C02559/1

Upper int. torque limit

C02559/2

Lower int. torque limit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C02560 | Messages - motor interface

Data type: UNSIGNED_32

Index: 22015

d

= 55FF

h

Motor interface

Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02561 | Speed feedforw. control gain

Data type: INTEGER_32

Index: 22014

d

= 55FE

h

Percentage reduction of the speed feedforward control of the profile generator

• Required in some applications if a 100 % speed feedforward control causes overshoots.

• Only effective for the basic functions "Positioning", "Homing" and "Manual jog".

Motor interface

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

200.00 100.00 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C02562 | Filter time constant

Data type: UNSIGNED_32

Index: 22013

d

= 55FD

h

From software version V2.0

Motor interface

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

60.000 0.002 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000