C00011 | motor reference speed, C00018 | switching frequency, C00019 | threshold - standstill recognition – Lenze E94AxPExxxx User Manual

Page 759: C00022 | maximum current, C00034 | config. analog input 1, C00018, C00022, A" in, C00011, He maximum current

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

759

15

Parameter reference

15.2

Parameter list | C00011

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00011

C00018

C00019

C00022

C00034

Parameter | Name:

C00011 | Motor reference speed

Data type: UNSIGNED_32

Index: 24564

d

= 5FF4

h

For parameter setting via interface: In case of bigger changes, only change the setting in one step when the

controller is inhibited!
Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

50000 3000 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00018 | Switching frequency

Data type: UNSIGNED_32

Index: 24557

d

= 5FED

h

Selection list

(Lenze setting printed in bold)

Info

2 1 kHz fixed/drive-optimised

Note:

• The maximum output frequency of the controller is

limited to 1/8 of the switching frequency selected

here!

• The switching frequencies that can be selected

depend on the device type (see Hardware Manual,

chapter "Rated data").

• In the case of an offline parameter setting or when

exchanging the memory module between different

Servo Drives 9400 PLC device types, always check the

setting of this parameter and adapt it, if required, to

prevent a parameter error after the parameter set

download or module change!

3 2 kHz fixed/drive-optimised
4 4 kHz fixed/drive-optimised
5 8 kHz fixed/drive-optimised
8 2 kHz var./drive-optimised
9 4 kHz var./drive-optimised

10 8 kHz var./drive-optimised
11 16 kHz var./drive-optimised

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00019 | Threshold - standstill recognition

Data type: UNSIGNED_32

Index: 24556

d

= 5FEC

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

450 5 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00022 | Maximum current

Data type: UNSIGNED_32

Index: 24553

d

= 5FE9

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A

21474836.47 0.00 A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00034 | Config. analog input 1

Data type: UNSIGNED_32

Index: 24541

d

= 5FDD

h

Selection list

(Lenze setting printed in bold)

0 -10...+10 V
1 -20...-4 mA, +4...+20 mA
2 -20 ... +20 mA

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising