In a CAN network, the node guarding protocol serves to monitor the connection between the NMT

master and the NMT slave(s). If the controller was parameterised as NMT master, it can monitor up

to 32 NMT slaves.

Basic workflow

[10-9] Node guarding protocol

1. The NMT master within cyclic time intervals sends a data telegram to the NMT slave, which is

referred to as "Remote Transmission Request" (RTR).

2. The NMT slave then returns a response telegram ("Response") to the NMT master.

t: Toggle bit

s: NMT slave status (4: Stopped, 5: Operational, 127: Pre-Operational)