Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

237

6

Motor interface

6.6

V/f control (VFCplus)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.6.2.1

Defining a user-defined V/f characteristic

To individually adjust the motor magnetisation to the real application, a user-definable

characteristic can be selected in

C00950

if the linear and square-law characteristic are not suitable.

• The interpolation points (voltage/frequency values) of this characteristic are selected via the 11

subcodes of

C00952

and

C00953

.

• If less interpolation points are required, the interpolation points that are not needed have to be

deactivated via the subcodes of

C00954

.

• In the Lenze setting the 11 grid points represent a linear characteristic:

[6-18] User-definable characteristic (Lenze setting)

P1

P2

P3

P4

P5

P6

P7

P8

P9

P10

P11

V

400 V

320 V

240 V

160 V

80 V

0 V

80 V

160 V

240 V

320 V

400 V

f

-50 Hz

-40 Hz

-30 Hz

-20 Hz

-10 Hz

0 Hz

10 Hz

20 Hz

30 Hz

40 Hz

50 Hz

U [V]

160

0

f [Hz]

240

320

400

10

20

30

40

50

-50

-40

-30

-20

-10

80

C00952/1
C00953/1

C00952/2
C00953/2

C00952/3
C00953/3

C00952/11
C00953/11

P1

P2

P3

P4

P5

P7

P6

P8

P9

P10

P11

Advertising