Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

161

5

Drive interface

5.6

Internal interfaces | "LS_DriveInterface" system block

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.6.1

Status signals

The following representation shows which status signals of the drive interface are set to TRUE in

different typical cases:

Case 1:

Application has been transmitted to the controller.

No mains voltage available (LU fault).

Controller is inhibited (via RFR terminal).

Case 2:

Mains voltage has been connected.

Case 3:

Controller inhibit has been deactivated.

Case 4:

Fault is active.

Case 5:

Quick stop by trouble is active

Status

Status signal (output)

Ready for operation

DI_bReady

Fault active

DI_bFailActive

Pulse inhibit active

DI_bImpActive

Controller inhibit active

DI_bCInhActive

Warning is active

DI_bWarningActive

Undervoltage detected

DI_bUVDetected

Overvoltage detected

DI_bOVDetected

Mains supply is ok

DI_bMainSupplyOk

Ready to switch on

DI_bReadyToSwitchOn

Operation enabled

DI_bOperationEnabled