C00776 | mctrl_dninputjerkctrl, C00777 | mctrl_dninputtorquectrl, C00778 | mctrl_dnfluxact – Lenze E94AxPExxxx User Manual

Page 838: C00779 | mctrl_dndcbusvoltage, C00780 | mctrl_dnimotact, C00780, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00776

838

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00776

C00777

C00778

C00779

C00780

Parameter | Name:

C00776 | MCTRL_dnInputJerkCtrl

Data type: INTEGER_32

Index: 23799

d

= 5CF7

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-21474836.47

Nm

21474836.47

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00777 | MCTRL_dnInputTorqueCtrl

Data type: INTEGER_32

Index: 23798

d

= 5CF6

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-21474836.47

Nm

21474836.47

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00778 | MCTRL_dnFluxAct

Data type: INTEGER_32

Index: 23797

d

= 5CF5

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-200.00

%

200.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00779 | MCTRL_dnDCBusVoltage

Data type: INTEGER_32

Index: 23796

d

= 5CF4

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0

V

1000

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00780 | MCTRL_dnImotAct

Data type: INTEGER_32

Index: 23795

d

= 5CF3

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-500.00

A

500.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Advertising