4 operation, 1 selecting the variables to be recorded, Oscilloscope toolbar – Lenze E94AxPExxxx User Manual

Page 614: Selecting the variables to be recorded, 13 oscilloscope

Advertising
background image

13

Oscilloscope

13.4

Operation

614

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Oscilloscope toolbar

13.4

Operation

This chapter describes step-by-step how to record the signal characteristics of controller variables

and represent, analyse, document and process them in the oscilloscope.

13.4.1

Selecting the variables to be recorded

The oscilloscope supports up to eight channels, i.e. max. eight variables can be recorded in a data

set.

How to add a variable for recording::

1. Double-click the line highlighted in grey in the Vertical channel settings list field.
2. Select the desired variable in the Select variable dialog box.
3. Click OK.

• The dialog box is closed and the selection is accepted.

4. Repeat steps 1 ... 3 to select up to seven more variables to be recorded.

The selected variables are displayed in the Vertical channel settings list field. Click into a field to

change the corresponding setting:

Icon

Function

Loading the oscillogram ( 624)

Closing the oscillogram ( 625)

Saving the oscillogram ( 623)

Copy to clipboard: Copy as text | Copy as image

• For documentation purposes, it is possible to copy the measured data of a data set as a table or,

alternatively, the oscilloscope user interface as a picture, to the clipboard for use in other

programs.

Printer settings | Print view | Print

Activate zoom function

Adjusting the representation ( 619)

Activate automatic scaling function

Adjusting the representation ( 619)

Load recorded oscillogram from device

• Transfer data from the measured data memory of the controller to the Engineering PC as data

record.

• Only possible when an online connection has been established to the controller.

Note!

The configuration of the oscilloscope and the start of recording are only possible when

an online connection has been established to the controller.

Advertising