C02710 | delay lim. speed, C02711 | s-ramp time lim. speed, C02712 | decel. time lim. speed – Lenze E94AxPExxxx User Manual

Page 909: C02713 | max. dist. manual control, C02710/1, C02711/1, C02710/2, C02711/2, C02710/3, C02711/3

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

909

15

Parameter reference

15.2

Parameter list | C02710

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02710

C02711

C02712

C02713

Parameter | Name:

C02710 | Delay lim. speed

Data type: UNSIGNED_32

Index: 21865

d

= 5569

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

0.0000

Unit/s²

214748.3647

Subcodes

Lenze setting

Info

C02710/1

0.0100 Unit/s²

Delays for limited speed 1 ... 4

C02710/2

0.0100 Unit/s²

C02710/3

0.0100 Unit/s²

C02710/4

0.0100 Unit/s²

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02711 | S-ramp time lim. speed

Data type: UNSIGNED_32

Index: 21864

d

= 5568

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

0

ms

10000

Subcodes

Lenze setting

Info

C02711/1

100 ms

S-ramp times for limited speed 1 ... 4

C02711/2

100 ms

C02711/3

100 ms

C02711/4

100 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02712 | Decel. time lim. speed

Data type: UNSIGNED_32

Index: 21863

d

= 5567

h

Basic function "

Limiter

"

Display range

(min. value | unit | max. value)

0

ms

10000

Subcodes

Info

C02712/1

Deceleration times for limited speed 1 ... 4

C02712/2
C02712/3
C02712/4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02713 | Max. dist. manual control

Data type: UNSIGNED_32

Index: 21862

d

= 5566

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit

214748.3647 360.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000