C00202 | autom. enp data transfer, C00203 | hw product types, C00204 | hw serial numbers – Lenze E94AxPExxxx User Manual

Page 781: C00203, C00204, 15 parameter reference

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

781

15

Parameter reference

15.2

Parameter list | C00202

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00202

C00203

C00204

Parameter | Name:

C00202 | Autom. ENP data transfer

Data type: UNSIGNED_32

Index: 24373

d

= 5F35

h

Selection list

(Lenze setting printed in bold)

0 Off
1 On

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00203 | HW product types

Data type: VISIBLE_STRING

Index: 24372

d

= 5F34

h

Subcodes

Info

C00203/1

Type: Control card

C00203/2

Type: Power section

C00203/3

Type: Module in MXI1

C00203/4

Type: Module in MXI2

C00203/5

Type: Memory module

C00203/6

Type: Safety module

C00203/7

Type: Standard device

C00203/8

Type: Complete device

C00203/9

Type: ENP

Read access  Write access  CINH  PLC-STOP  No transfer

Scaling factor: 1

Character length: 18

Parameter | Name:

C00204 | HW serial numbers

Data type: VISIBLE_STRING

Index: 24371

d

= 5F33

h

Subcodes

Info

C00204/1

Serial no.: Control card

C00204/2

Serial no.: Power section

C00204/3

Serial no.: Module in MXI1

C00204/4

Serial no.: Module in MXI2

C00204/5

Serial no.: Memory module

C00204/6

Serial no.: Safety module

C00204/7

Serial no.: Standard device

C00204/8

Serial no.: Complete device

C00204/9

Serial no.: ENP

Read access  Write access  CINH  PLC-STOP  No transfer

Scaling factor: 1

Character length: 22