C00569

C00570

C00571

C00572

Parameter | Name:

C00569 | Resp. brake trans. ixt > C00570

Data type: UNSIGNED_32

Index: 24006

d

= 5DC6

h

Response if adjustable warning threshold (

C00570

) of brake chopper monitoring is reached.

Braking operation

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00570 | Warning thres. brake transistor

Data type: UNSIGNED_32

Index: 24005

d

= 5DC5

h

Warning threshold for brake chopper monitoring

• The response to reaching the threshold can be selected in

C00569

.

Braking operation

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 90 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00571 | Resp. to brake res. i²xt > C00572

Data type: UNSIGNED_32

Index: 24004

d

= 5DC4

h

Response if adjustable warning threshold (

C00572

) of brake resistor monitoring is reached.

Braking operation

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00572 | Warning thres. brake resistor

Data type: UNSIGNED_32

Index: 24003

d

= 5DC3

h

Warning threshold for brake resistor monitoring

• The response to reaching the threshold can be selected in

C00571

.

Braking operation

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 90 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1