3 carrying out positioning, 1 starting positioning, 2 aborting/interrupting positioning – Lenze E94AxPExxxx User Manual

Page 517: Starting positioning, Aborting/interrupting positioning, 12 basic drive functions

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

517

12

Basic drive functions

12.7

Positioning

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.7.3

Carrying out positioning

Preconditions

• The controller is in the "Operation" device state.
• The basic function "Positioning" is part of the active application.
• No other basic function is active.

Activation
To request the control via the basic function, the POS_bEnable enable input in the application must

be set to TRUE.

• If no other basic function is active, a change-over to the "Positioning active" function state is

effected and positioning can be carried out via the control inputs.

• A successful change to the function state "Positioning active" is displayed by a TRUE signal at the

POS_bEnabled status output.

Deactivation
When the POS_bEnable enable input is reset to FALSE, an active positioning is stopped, i.e. the

control inputs for positioning are inhibited and the drive is braked to standstill within the

deceleration time for stop.

• The status output POS_bEnabled is reset to FALSE and a change-over from the active

"Positioning active" function state via the "Drive is stopped" function state back to the basic

state "Drive at standstill" is carried out.

12.7.3.1

Starting positioning

By setting the control input POS_bStart to TRUE, the positioning process is started.

• The (travel) profile that has been transferred to the basic function via the input POS_ProfileData

is traversed.

12.7.3.2

Aborting/interrupting positioning

By setting the control input POS_bAbort to TRUE, the active positioning can be aborted or

interrupted.

• The current profile is not completed but braked to standstill with the deceleration defined in the

profile data.

• If the control input POS_bAbort remains on TRUE, a restart or the continuation of an interrupted

positioning is inhibited.

• After resetting the control input POS_bAbort to FALSE, a restart or the continuation of an

interrupted positioning process is possible again.

Advertising