611

13

Oscilloscope

13.1

Technical data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13

Oscilloscope

The oscilloscope function integrated in the controller can be used as support for commissioning,

maintenance, and troubleshooting.

Typical applications

• Graphical representation of any measured values (e.g. speed setpoint, actual speed, and torque)
• Detection of process values without additional measuring instruments (e.g. oscilloscope,

voltmeter and ammeter)

• Convenient documentation for fine tuning of control circuits or parameter changes of the

controller

• Documentation of production quality in the context of product liability and quality assurance

Special features

• Recording and saving measured values in the controller
• Simultaneous measuring on eight independent channels
• Measuring of fast and slow signals by means of adjustable sample rate
• Triggering on channel, variable, or error message
• Detecting of measured values before and after a trigger event (pre-/post-trigger)
• Graphical representation and evaluation of measured values on a PC
• Cursor and zoom function for the measurement analysis
• Saving & loading of oscilloscope configurations
• Export of measured values via the clipboard for further processing

13.1

Technical data

13.2

Functional description

With an online connection to the controller, use the oscilloscope user interface of »Engineer« to set

the trigger condition and the sample rate and select the variables to be recorded.

9400 Servo Drives
Memory depth

Max. 16384 measured values, depending on the number of channels and the size of

the variables to be recorded.

Memory capacity

32768 bytes

Data width of a channel

1 ... 4 bytes, corresponding to the size of the variables to be recorded

Number of channels

1 ... 8

Trigger level

Corresponding to the value range of the variable to be triggered

Trigger selection

Immediate triggering, rising/falling edge, signal change

Trigger delay

-100 % ... +400 %

Trigger source

Channels 1 ... 8, any variable or error message

Max. time base

8 channels 32 bits each ≡ 26 hours

Max. recording time

8 channels 32 bits each ≡ 10 days

Advertising