6.5.1.1

Parameterising speed and torque controller

Short overview: Parameters for controller settings

Typical controller settings
The following table contains typical guide values concerning the setting of the speed and torque

control for different device types/motor powers:

[6-8]

Typical controller settings

The gain for the field current controller (

C00985

) and the gain for the cross current controller

(

C00986

) are initially set to "0.00".

Parameter

Info

Lenze setting

Value Unit

C00070

Speed controller gain

0.500 Nm/rpm

C00071

Speed controller reset time

24.0 ms

C00987

SLVC: Torque controller gain

0.5000 Hz/A

C00988

SLVC: Torque controller reset time

10.00 ms

Device type

Motor power

Speed controller

Torque controller

E94ASx

(4-pole standard

ASM)

Gain

C00070

[Nm/rpm]

Reset time

C00071

[ms]

Gain

C00987

[Hz/A]

Reset time

C00988

[ms]

E0024

0.37 kW

0.0122

50.00

5.0833

10.00

E0034

0.75 kW

0.0138

50.00

3.0500

10.00

E0044

1.50 kW

0.0264

50.00

1.9818

10.00

E0074

3.00 kW

0.0411

50.00

1.1077

10.00

E0134

5.50 kW

0.0674

50.00

0.5965

10.00

E0174

7.50 kW

0.1183

50.00

0.3303

10.00

E0244

11.00 kW

0.1183

50.00

0.3303

10.00

E0324

15.00 kW

0.2244

50.00

0.2368

10.00

E0474

22.00 kW

0.3442

50.00

0.1547

10.00

E0594

30.00 kW

1.1503

50.00

0.1232

10.00

E0864

45.00 kW

1.7400

50.00

0.0817

10.00

E1044

55.00 kW

2.1712

50.00

0.0661

10.00