9 monitoring, 1 signal flow, Monitoring – Lenze E94AxPExxxx User Manual

Page 262: Signal flow, 6motor interface, 9 monitoring 6.9.1 signal flow

Advertising
background image

6

Motor interface

6.9

Monitoring

262

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.9

Monitoring

6.9.1

Signal flow

[6-33] Signal flow of motor interface (monitoring)

Internal variables of the motor control (oscilloscope signals)

• The red numbers in brackets listed in the signal flow stand for internal variables of the motor

control, which you can record by means of the

Oscilloscope

for purposes of diagnostics and

documentation.

( 611)

a +b

2

2

S

DI_bOVDetected

DI_bUVDetected

MCTRL_dnIxtLoad

const.

const.

const.

MCTRL_dnI2xtLoad

C00597
C00599

C00173
C00174

C00128
C00129

C00786

C00120

C00790

MCTRL_dnDCBusVoltage

C00779

MI_bMotorOverloadWarning

C00053

³1

MI_dnActualDCBusVoltage

(15)

C00055/1

C00055/2

C00055/3

U

V

W

(16)

(17)

(18)

C00018
C00022

const.

Error message
"Failure of motor phase"

Error message "Earth fault detected"

DC-bus voltage

DC-bus voltage filter

Phase currents

Thermal motor model

DC-bus voltage

Actual Q-current

Actual D-current

Error message "Overcurrent detected"

Rotating field frequency

No. Variable of the motor control

Meaning

(15) Voltage.dnActualDCBusVoltage

Actual DC-bus voltage

(16) Current.dnActualCurrentPhaseU

Actual motor current (phase U)

(17) Current.dnActualCurrentPhaseV

Actual motor current (phase V)

(18) Current.dnActualCurrentPhaseW

Actual motor current (phase W)