Parameter list | C00469

816

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00469

C00490

C00494

C00495

Parameter | Name:

C00469 | Keypad: Fct. STOP key

Data type: UNSIGNED_8

Index: 24106

d

= 5E2A

h

Selection list

(Lenze setting printed in bold)

0 No response
1 Inhibit controller
2 Activate quick stop
3 Stop application

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00490 | Position encoder selection

Data type: UNSIGNED_16

Index: 24085

d

= 5E15

h

Chapter "

Controller configuration

" provides you with more information on parameter setting.

Selection list

(Lenze setting printed in bold)

0 Resolver on X7
1 Encoder on X8
4 Encoder signal on LS_Feedback

10 Motor encoder (C00495)

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00494 | Motor standstill time constant

Data type: UNSIGNED_32

Index: 24081

d

= 5E11

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

100000 0 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00495 | Motor encoder selection

Data type: UNSIGNED_16

Index: 24080

d

= 5E10

h

Selection list

(Lenze setting printed in bold)

0 Resolver on X7
1 Encoder on X8

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1