89

5

Drive interface

5.1

Machine parameters

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Note!

The position values (e.g. setpoints, actual values, parameters, …) in the signal flow

always use the resolution set in

C00100

. In this connection it is irrelevant which

resolution is delivered directly by the encoder.
Multi-axis systems
In an interconnection via the electrical shaft, at least two measuring systems (master

and slave) are available in the drive.

• Each measuring system is provided with an individual setting of the resolution.
• The machine parameters (gearbox factors, feed constants, encoder resolution and

cycle) for the master measuring system or master value must be set identically for all

drives in the system.

Technology applications "Electronic gearbox" and "Synchronism"
For these two technology applications the machine parameters of the master measuring

system are defined on the Application parameters tab in the "Master value scaling"

dialog level.
Electronic cam
The machine parameters of the master measuring system for electronic cams can be

defined on the Measuring systems tab for the electrical shaft.