C02603 | threshold 1 for opening brake, C02604 | threshold 2 for opening brake, C02605 | brake test - time – Lenze E94AxPExxxx User Manual

Page 890: C02607 | brk_dnstate, C02608 | brk_dntorqueadd_n, C02608, C02607, C02603, C02604, To set

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02603

890

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02603

C02604

C02605

C02607

C02608

Parameter | Name:

C02603 | Threshold 1 for opening brake

Data type: INTEGER_32

Index: 21972

d

= 55D4

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

-50000

rpm

50000 0 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02604 | Threshold 2 for opening brake

Data type: INTEGER_32

Index: 21971

d

= 55D3

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

-50000

rpm

50000 0 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02605 | Brake test - time

Data type: UNSIGNED_16

Index: 21970

d

= 55D2

h

From software version V4.0

Setting range

(min. value | unit | max. value)

0.001

s

65.535

Subcodes

Lenze setting

Info

C02605/1

1.024 s

Brake test - ramp-up time

C02605/2

4.000 s

Brake test - constant ph. time

C02605/3

1.024 s

Brake test - ramp-down time

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02607 | BRK_dnState

Data type: INTEGER_32

Index: 21968

d

= 55D0

h

Bit coded status of the basic function "

Brake control

".

Display range

(min. value | unit | max. value)

-2147483648

2147483647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02608 | BRK_dnTorqueAdd_n

Data type: INTEGER_32

Index: 21967

d

= 55CF

h

Display of the additive torque value of the basic function "

brake control

".

Display range

(min. value | unit | max. value)

-200.00

%

200.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100