C00985

C00986

C00987

C00988

C00989

Parameter | Name:

C00985 | SLVC: Field current controller gain

Data type: UNSIGNED_32

Index: 23590

d

= 5C26

h

Sensorless vector control

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

21474836.47 0.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00986 | SLVC: Cross current controller gain

Data type: UNSIGNED_32

Index: 23589

d

= 5C25

h

Sensorless vector control

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

21474836.47 0.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00987 | SLVC: Gain - torque controller

Data type: UNSIGNED_32

Index: 23588

d

= 5C24

h

Sensorless vector control

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Hz/A

1000.0000 0.5000 Hz/A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C00988 | SLVC: Reset time - torque contr.

Data type: UNSIGNED_32

Index: 23587

d

= 5C23

h

Sensorless vector control

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

ms

2000.00 10.00 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00989 | SLVC: Time const.- Para. adj.

Data type: UNSIGNED_32

Index: 23586

d

= 5C22

h

Sensorless vector control

Setting range

(min. value | unit | max. value)

0

ms

20000

Subcodes

Lenze setting

Info

C00989/1

20000 ms

SLVC: Time const.- Para.Rs adj.

C00989/2

20000 ms

SLVC: Time const.- Para.Lh adj.

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1