2 manual jog with step limitation, Manual jog with step limitation, Manual jog with step limitation ( 442) – Lenze E94AxPExxxx User Manual

Page 442: 12 basic drive functions

Advertising
background image

12

Basic drive functions

12.4

Manual jog

442

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.4.3.2

Manual jog with step limitation

This mode can be activated via the control input MAN_bStepMode.
In the "Manual jog with step limitation" mode the drive traverses by the "step distance"

parameterised in

C02625

if a direction is requested via the control inputs MAN_bJogPositive/

MAN_bJogNegative. After traversing this distance, the drive stops.

• A new positive edge for the routing request causes a restart of the function or a reset of the

distance counter, even if the drive is not at standstill yet.

• If the routing request is reset before the distance is reached, the drive stops immediately (with

the deceleration set).

Note!

The two modes "Manual jog with step limitation" and "Manual jog with intermediate

stop" cannot be active at the same time.
If there is a simultaneous request via the control inputs MAN_bStepMode and

MAN_bIntermediateStopMode, only the "Manual jog with intermediate stop" mode is

active.

Manual jog with intermediate stop

( 443)