New application loaded [0x006a0003, User task 1: overflow [0x006a0004, User task 2: overflow [0x006a0005 – Lenze E94AxPExxxx User Manual

Page 668: User task 3: overflow [0x006a0006, User task 4: overflow [0x006a0007, 0x006a0003, 0x006a0004, 0x006a0005, 0x006a0006, 0x006a0007

Advertising
background image

14

Diagnostics & fault analysis

14.7

Error messages of the operating system

668

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

New application loaded [0x006a0003]

User task 1: Overflow [0x006a0004]

User task 2: Overflow [0x006a0005]

User task 3: Overflow [0x006a0006]

User task 4: Overflow [0x006a0007]

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

3

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Application has been changed by transmission from

Engineer or loading from the memory module.

- (Information only)

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

4

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Program runtime in user task 1 is too high.

Reduce program runtime by means of:

• Omitting functions (e.g. by reducing the number of

active FBs).

• Optimisation of functions to the calculating time.

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

5

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Program runtime in user task 2 is too high.

See remedy for "

User task 1: Overflow

".

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

6

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Program runtime in user task 3 is too high.

See remedy for "

User task 1: Overflow

".

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

7

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Program runtime in user task 4 is too high.

See remedy for "

User task 1: Overflow

".

Advertising