12
Basic drive functions
12.5
Manual job, encoderless
450
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.5.2.3
Deactivation
The basic function is deactivated by
• setting the input "MOL_bEnable" to FALSE or
• removing the checkmark (if there is one) in the »Engineer« dialog box entitled Manual control
(parameter set 1).
[12-21] Deactivation of the basic function "Manual jog, encoderless"
Stop!
Before the basic function is deactivated, the controller inhibit must be set. Otherwise,
unsteady drive behaviour can occur when a changeover is made from the basic function
"Manual jog, encoderless" to the basic function "Stop".