C00398 | test mode motor control, C00399 | settings for test mode, C00412 | hiperface: initialisation time – Lenze E94AxPExxxx User Manual

Page 809: C00398, C00412, C00399/1, 15 parameter reference

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

809

15

Parameter reference

15.2

Parameter list | C00396

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00396

C00397

C00398

C00399

C00412

Parameter | Name:

C00396 | Service code

Data type: UNSIGNED_32

Index: 24179

d

= 5E73

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00397 | Service code

Data type: UNSIGNED_32

Index: 24178

d

= 5E72

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00398 | Test mode motor control

Data type: UNSIGNED_32

Index: 24177

d

= 5E71

h

Danger!

When the test mode is activated, the parameterisable error response "Quick stop by trouble" has no effect!

If the test mode is active and a monitoring function responds with this error response, no quick stop is executed but

the motor continues to rotate with the frequency set for the test mode!
Selection list

(Lenze setting printed in bold)

Info

0 Test mode deactivated
1 U rotation test mode
2 I rotation test mode
3 Current controller optimisation

mode

After controller enable, the motor is supplied with

current as long as the controller is enabled.

4 Current controller optimisation

mode impulse

The motor is supplied with voltage for 50 ms after

controller enable. Due to this time limit, the load of the

machine is reduced. Afterwards, the controller is

inhibited automatically.

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00399 | Settings for test mode

Data type: INTEGER_32

Index: 24176

d

= 5E70

h

Setting range

(min. value | unit | max. value)

-1000.0

Hz/1°

1000.0

Subcodes

Lenze setting

Info

C00399/1

0.0 Hz/1°

Frequency [Hz] for test mode

C00399/2

0.0 Hz/1°

Start angle [°] for test mode

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00412 | Hiperface: Initialisation time

Data type: UNSIGNED_32

Index: 24163

d

= 5E63

h

From software version V5.0

Parameterisation of a Hiperface encoder with increased initialisation time

Setting range

(min. value | unit | max. value)

Lenze setting

150

ms

2000 650 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising