C00974 | DC brake: Current

Data type: INTEGER_32

Index: 23601

d

= 5C31

h

DC-injection braking

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A

500.00 0.00 A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00975 | DC brake: Current for quick stop

Data type: INTEGER_32

Index: 23600

d

= 5C30

h

DC-injection braking

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A

500.00 0.00 A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00976 | DC brake: Activat. by quick stop

Data type: UNSIGNED_32

Index: 23599

d

= 5C2F

h

DC-injection braking

Selection list

(Lenze setting printed in bold)

0 Off
1 On

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00977 | Min. inh-time aft. overvolt

Data type: UNSIGNED_32

Index: 23598

d

= 5C2E

h

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

1

ms

10000 500 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00980 | VFC: Override point of field weakening

Data type: INTEGER_32

Index: 23595

d

= 5C2B

h

From software version V2.0

Offset of the override point for field weakening

• In the VFCplus operating mode the pull-out protection function or the maximally permissible current in the field

weakening range can be adapted.

Setting range

(min. value | unit | max. value)

Lenze setting

-500

Hz

500 0 Hz

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1