2 select motor control, Select motor control, 6motor interface – Lenze E94AxPExxxx User Manual

Page 169

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

169

6

Motor interface

6.2

Select motor control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.2

Select motor control

In

C00006

the motor control is selected; the default is the servo control for synchronous motors.

Alternatively to the servo control, also the V/f control and the sensorless vector control are provided

in

C00006

:

• The V/f control is the classic operating mode for standard applications.
• Compared to the V/f control, improved drive characteristics can be achieved with sensorless

vector control by:

• a higher torque across the entire speed range
• a higher speed accuracy and a higher concentricity factor
• Higher efficiency

[6-1]

Comparison of V/f control and sensorless vector control

Open/closed loop control

Detailed information

1 SC: Servo control for synchronous motor

Servo control (SC) ( 190)

2 SC: Servo control for asynchronous motor

4 SLVC: Sensorless vector control

Sensorless vector control (SLVC) ( 211)

6 VFCplus: V/f control open loop

V/f control (VFCplus) ( 229)

7 VFCplus: V/f control closed loop

V/f control (VFCplus) ( 245)

V/f control

Sensorless vector control

M

n

n

N

M

N

Œ



Note!

Sensorless vector control (SLVC) is only approved for powers up to 55 kW and horizontal

applications (no hoists or lifting equipment)!

Advertising