15

Parameter reference

15.2

Parameter list | C00995

854

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00995

C00998

C01120

Parameter | Name:

C00995 | Flying restart: Delay time

Data type: UNSIGNED_32

Index: 23580

d

= 5C1C

h

Flying restart function

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

10000 0 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00998 | VFC: Frequency setpoint

Data type: INTEGER_32

Index: 23577

d

= 5C19

h

V/f control

Display range

(min. value | unit | max. value)

-800.0

Hz

800.0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C01120 | Sync source

Data type: UNSIGNED_8

Index: 23455

d

= 5B9F

h

Selection of the source for the synchronisation signals.

• The drive can only be synchronised by one source.

Note:

Set the selection "2: CAN module" for the communication module CANopen (E94AYCCA).

"CAN on board" system bus: sync telegram

Selection list

(Lenze setting printed in bold)

0 Off
1 CAN on board
2 CAN module
4 Module in MXI1
5 Module in MXI2
6 Digital input 1
7 Digital input 2
8 Digital input 3
9 Digital input 4

10 Digital input 5
11 Digital input 6
12 Digital input 7
13 Digital input 8

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1