2 parameter setting, 3 execute pole position identification, 12 basic drive functions – Lenze E94AxPExxxx User Manual

Page 605

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

605

12

Basic drive functions

12.14

Pole position identification

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.14.2

Parameter setting

• Parameterisation dialog in »Engineer«: Tab Application parameters  Dialog level Overview

All basic functions Pole position identification

• Short overview of parameters for pole position identification:

12.14.3

Execute pole position identification

Preconditions

• The controller inhibit is active.
• The controller has the "Controller not ready" function state.
• The basic function "Pole position identification" is part of the active application.
• No other basic function is active.

Activate basic function
To request the control via the basic function, the PPI_bEnable enable input in the application must

be set to TRUE.

• If no other basic function is active, a change-over to the "Identification of pole position active"

function state is effected and an identification of pole position can be carried out via the control

inputs.

• A successful change to the function state "Pole position identification" is displayed by a TRUE

signal at the PPI_bEnabled status output.

Parameter

Info

C02785

Activation of PPI

C02786

Mode of PPI

C02787

Ppi_dnState

C02788

PolePosition Setpoint

C02789

PolePositionIdentification: Dig. signals

Highlighted in grey = display parameter