Parameter list | C02549

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02549

C02550

C02552

Parameter | Name:

C02549 | Drive interface: Signals

Data type: UNSIGNED_32

Index: 22026

d

= 560A

h

Display of the digital signals of the

drive interface

.

Selection list

(read only)

0 FALSE
1 TRUE

Subcodes

Info

C02549/1

DI_bSetCInh

C02549/2

Reserved

C02549/3

Reserved

C02549/4

DI_bSwitchOn

C02549/5

Reserved

C02549/6

DI_bReady

C02549/7

DI_bFailActive

C02549/8

DI_bImpActive

C02549/9

DI_bCinhActive

C02549/10

DI_bWarningActive

C02549/11

DI_bUVDetected

C02549/12

DI_bOVDetected

C02549/13

DI_bMainSupplyOk

C02549/14

DI_bReadyToSwitchOn

C02549/15

DI_bOperationEnabled

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02550 | Setpoint interpolation

Data type: UNSIGNED_32

Index: 22025

d

= 5609

h

Motor interface

Selection list

0 Off
1 On

Subcodes

Lenze setting

Info

C02550/1

1: On

Position setpoint interpolat.

C02550/2

1: On

Speed setpoint interpolat.

C02550/3

1: On

Torque setpoint interpolat.

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02552 | Position setpoint (mctrl)

Data type: INTEGER_32

Index: 22023

d

= 5607

h

Motor interface

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000