_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

CAN on board RPDO1: Telegram not received or faulty [0x00870000]

CAN on board RPDO2: Telegram not received or faulty [0x00870001]

CAN on board RPDO3: Telegram not received or faulty [0x00870002]

CAN on board RPDO4: Telegram not received or faulty [0x00870003]

Module ID (decimal)

Error ID (decimal)

135: "CAN on board": CAN-PDO handler

0

Response (Lenze setting printed in bold)

Setting:

C00591/1

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CAN on board: CAN-IN 1 error

• Incorrect PDO telegram length.

• Transmission error.

• Time monitoring of the PDOs has tripped.

• Set correct telegram length for CAN master

(transmitter).

• Eliminate trouble in the environment (e. g. EMC).

• Select a different time monitoring or switch off time

monitoring.

Module ID (decimal)

Error ID (decimal)

135: "CAN on board": CAN-PDO handler

1

Response (Lenze setting printed in bold)

Setting:

C00591/2

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CAN on board: CAN-IN 2 error

• Incorrect PDO telegram length.

• Transmission error.

• Time monitoring of the PDOs has tripped.

• Set correct telegram length for CAN master

(transmitter).

• Eliminate trouble in the environment (e. g. EMC).

• Select a different time monitoring or switch off time

monitoring.

Module ID (decimal)

Error ID (decimal)

135: "CAN on board": CAN-PDO handler

2

Response (Lenze setting printed in bold)

Setting:

C00591/3

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CAN on board: CAN-IN 3 error

• Incorrect PDO telegram length.

• Transmission error.

• Time monitoring of the PDOs has tripped.

• Set correct telegram length for CAN master

(transmitter).

• Eliminate trouble in the environment (e. g. EMC).

• Select a different time monitoring or switch off time

monitoring.

Module ID (decimal)

Error ID (decimal)

135: "CAN on board": CAN-PDO handler

3

Response (Lenze setting printed in bold)

Setting:

C00591/4

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CAN on board: CAN-IN 4 error

• Incorrect PDO telegram length.

• Transmission error.

• Time monitoring of the PDOs has tripped.

• Set correct telegram length for CAN master

(transmitter).

• Eliminate trouble in the environment (e. g. EMC).

• Select a different time monitoring or switch off time

monitoring.