Homing mode not allowed [0x00b80019, Ta" (error number, 0x00b80034 – Lenze E94AxPExxxx User Manual

Page 736: 0x00b80016, 0x00b80017, 0x00b80019, 14 diagnostics & fault analysis

Advertising
background image

14

Diagnostics & fault analysis

14.7

Error messages of the operating system

736

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Cam data locked due to incorrect password [0x00b80016]

Cam data locked due to incorrect safety key [0x00b80017]

Homing mode not allowed [0x00b80019]

Cam data: Invalidated due to change of mechanical data [0x00b80034]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

22

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The cam data were locked since the user password was

entered incorrectly for three times.

The cam data were not loaded.

Reset parameters to the Lenze setting via device

command

C00002

= "0: Load Lenze setting". Then

download cam data again.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

23

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The cam data were not loaded because the safety key is

damaged.

The password in the cam data or the serial number of the

memory module has been manipulated.

Reset parameters to the Lenze setting via device

command

C00002

= "0: Load Lenze setting". Then

download cam data again.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

25

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The homing mode selected in

C02640

is not supported in

the motor control type selected in

C00006

.

Select another homing mode in

C02640

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

52

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

One or several machine parameters which have an

influence on the internal scaling of the cam data have

been changed. The cam data have to be recalculated.

Execute device command

C00002

= "503: Calculate Cam

Data". This automatically resets the warning.

Advertising